http://williamstallings.com/COA6e.html
Redundant Array of Independent Disks
- Disk Performance = bottle neck of computer system
- RAID - better transfer with simultaneous access
- 7 Levels in common use (0-6)
- Not a hierarchy
- 운영체제에 의해 하나의 논리적 드라이브로 보여지는 물리적 디스크드라이브들의 집합이다.
- 데이터는 분산저장됨
- 여분의 디스크는 복구를 위한 패리티로 사용된다
0.1. Glossary
- Strip : physical blocks, sector
- Stripe : a set of logically consecutive strips
0.2. RAID Summary
RAID Levels
|| Category || Level || Description || I/O Request Rate (Read/Write) || Data Transfer Rate (Read/Write) || Typical Application ||
|| Striping || 0 ||Nonredundant || Large strips: Excellent || Small strips: Excellent || Applications requiring high performance for noncritical data ||
|| Mirroring || 1 ||Mirrored || Good/Fair || Fair/Fair || System drives; critical files ||
||<|2> Parallel access || 2 || Redundant via Hamming code || Poor || Excellent || ||
|| 3 || Bit-interleaved parity || Poor || Excellent || Large I/O request size applications, such as imaging, CAD ||
||<|3> Independent access || 4 || Block-interleaved parity || Excellent/Fair || Fair/Poor || ||
|| 5 || Block-interleaved distributed parity || Excellent/Fair || Fair/Poor || High request rate, read intensive, data lookup ||
|| 6 || Block-interleaved dual distributed parity || Excellent/Poor || Fair/Poor || Applications requiring extremely high availability ||
0.3. RAID 0
- No redundancy
- Asynchronous disks
- Data striped across all disks
- Round Robin striping
- Increase speed
- Multiple data requests probably not on same disk
- Disks seek in parallel
- A set of data is likely to be striped across multiple disks
- For performance and capacity
0.4. RAID 1
- Mirrored Disks
- Asynchronous disks
- Data is striped across disks as RAID0
- 2 copies of each stripe on separate disks
- Read from either
- Write to both - takes time( parallel )
- Recovery is simple
- Swap faulty disk & re-mirror
- No down time
- Expensive
0.5. RAID 2
- Disks are synchronized
- Very small stripes
- Often single byte/word
- Error correction calculated across corresponding bits on disks
- Multiple parity disks store Hamming code error correction in corresponding positions
- Lots of redundancy
- Expensive
- Not used
0.6. RAID 3
- Similar to RAID 2
- Bit level synchronized
- Only one redundant disk, no matter how large the array
- Simple parity bit for all of the corresponding bits of all the data disk
- Data on failed drive can be reconstructed from surviving data and parity info
- Very high transfer rates
- Example)
- Assume data drive X0 ~ X3, Parity disk X4, and X1 failed
- X4(i) = X3(i) @ X2(i) @ X1(i) @ X0(i) * @ X4(i) @ X1(i)
- X1(i) = X4(i) @ X3(i) @ X2(i) @ X0(i)
0.7. RAID 4
- Each disk operates independently
Good for high I/O request rate (can handle separate I/O request in parallel) Less suited for high data transfer rate Large stripes Bit by bit parity calculated across stripes on each disk Parity stored on parity disk Write penalty => 2 reads & 2 writes for a data write. Example) Assume data drive X0 ~ X3, Parity disk X4, and X1(i) changed, X4(i) = X3(i) @ X2(i) @ X1(i) @ X0(i) X4’(i) = X3(i) @ X2(i) @ X1’(i) @ X0(i) = X3(i) @ X2(i) @ X1’(i) @ X0(i) @ X1(i) @ X1(i) = X4(i) @ X1’(i) @ X1(i) = > read X1, X4; write X1’& X4’
0.8. RAID 5
Like RAID 4 Parity striped across all disks Round robin allocation for parity stripe Avoids RAID 4 bottleneck at parity disk Commonly used in network servers N.B. DOES NOT MEAN 5 DISKS!!!!!
0.9. RAID 6
2 Redundancy. double redundancy (parity + another check algorithm) High write penalty 2 disk fail can be recovered Extremely reliable
see also Computer Architecture, HD Tune